Rev. odontol. Univ. Cid. São Paulo (Online) ; 23(3)set.-dez. 2011. graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-621685

ABSTRACT

Objetivo: Este estudo propõe-se avaliar a perda de corte do instrumento rotatório ProTaper® em função do número de uso e esterilização em autoclave. Método: Foram estudados 10 canais simulados de resina acrílica transparente com ângulo de curvatura de 45º, valendo-se de instrumentos Protaper® de numeração S1, S2, F1, F2 e F3, substituindo o Sx pelas brocas de Largo #1. Os blocos foram pesados em balança analítica digital, anotando-se o peso inicial. A seguir, houve o preparo com motor elétrico Endo Pro-Torque® da Driller com reverso automático submetido ao ajuste e controle da velocidade em 350 rpm, torque de 1N, com engate para contra-ângulo modelo Kavo®, tomando-se o cuidado de padronizar o tempo de ação de cada instrumento em 3 minutos. Usou-se o creme de Endo-PTC durante o preparo do canal simulado e após seu tempo de ação, lavava-se o canal com hipoclorito de sódio. Depois, o bloco era lavado com detergente neutro, seco com gaze, canal aspirado, seco com cone de papel absorvente, pesado, anotando-se o peso final. A cada uso as limas rotatórias eram limpas com gaze embebido em álcool e, posteriormente, lavadas com detergente neutro e secas também com gaze e levadas em envelope descartável para processo de esterilização em autoclave com ciclo de 20 minutos. Resultados: Os instrumentos utilizados perderam a sua capacidade de corte em função do número de uso. Conclusão: O instrumento perde a capacidade de corte em função do uso, e só a partir do sé¬timo uso, o instrumento ProTaper® perde consideravelmente sua efetividade, recomendando-se seu descarte


Aims: This investigation aims to evaluate the cutting loss and sterilization of rotary ProTaper® instrument for sterilization process in autoclave. Method: Were studied ten substrate resin simulated canals blocks numbered 1 to 10 with angle of 45º. Before and after instrumentation were used with ProTaper® files numbering S1, S2, F1, F2, F3, is substituting for the Sx Largo drills # 1. These blocks were weighted using an analytical digital scale model Mettler AJ 100 and following it were analyzed of the amount of resin removed in each sample were noted both initial and final weight. The instrumentation was made with Endo-Pro-Torque engine-driven Driller system with automatic reverse and speed control in 350 rpm, torque 1N using stop watch for standardize the 3 minutes time of each instrument. Cream Endo-PTC was used during instrumentation e after that, washing the canals with 5mL the distillate water with plastic syringe. The blocks were washed with detergent, dry with gauze, aspirated canal, dried with paper absorbent points, weighted and noted final weight. In each use the files were clean with gauze alcohol soaked and later washed with detergent and dried with gauze and put in recipient discard able for sterilization in autoclave Sercon model during 20 minutes. Results: The instruments used have lost the cutting ability in relation to the number of use. Conclusions: It?s concluded that occurred a loss of efficiency of the cutting instrument, however the instrument ProTaper loses its cutting ability in use only after the seventh use and thus it?s recommended its discard


Subject(s)
Dental High-Speed Technique , Dental Cavity Preparation , Dental Instruments
SELECTION OF CITATIONS
SEARCH DETAIL